TCM 1 900 – Howmet Fixations Simmonds – St Cosme en Vairais (FR) 4JSMR10245 EN3538-040

QAR: Click Here
Conditions for approval required by:  Julien Gauther

4 Replies to “TCM 1 900 – Howmet Fixations Simmonds – St Cosme en Vairais (FR) 4JSMR10245 EN3538-040”

  1. Could you please update NADCAP MTL accreditation?
    For NADCAP CP, no update expected since HFS St Cosme is no longer accredited due to fire accident.

    Tensile tests at 80% and 100% loads: as per ISO5858, clause 5.6.1 and as per QTP, sections 5.6.1.1 and 5.6.1.2, 8 parts shall be tested for each tests.
    However, in QTR, we have 4 parts tested for each test.
    4 nuts missing for each tensile test.

    Many thanks in advance,
    Best regards.

    1. Dear Julien,
      conditions have been answered by HFS St Cosme:
      -update NADCAP MTL accreditation= OK done and updated,
      -Tensile tests at 80% and 100% loads: as per ISO5858, clause 5.6.1 and as per QTP, sections 5.6.1.1 and 5.6.1.2, 8 parts shall be tested for each tests. => Sampling test has well be done with 8 pieces, and results are compliant.
      Please see enclosed the updated QTR at issue A.

      Thank you in advance for your treatment,
      Antoine

      1. Mr. Diaz, please find below the reply to Mr. Gauther’s comments :

        Nadcap MTL accreditation is well uploaded.
        QTR updated in accordance with the remarks of M. Gauther

        Regards.
        Nadege

  2. Many thanks for updated QTR in additional document section.
    Fine for me now.
    Best regards.