TCM 1 693-Arconic Fixations Simmonds – St Cosme en Vairais (FR) EN4399-024, -027, -026, -034

QAR: Click Here
Conditions for approval required by:  Martin Russell

 

_________________________

One Reply to “TCM 1 693-Arconic Fixations Simmonds – St Cosme en Vairais (FR) EN4399-024, -027, -026, -034”

  1. Conditions:
    I cannot locate the ‘validation’ that defines or links the material used to EN2171 req’t.
    -The reference standard for these bars is EN4318.

    The Reuseability tests (QTR paras 4.1 & 4.2- 12 & 5 cycle tests for each ring size) indicate the samples were uncoated. Please add explanation why silver plated products were tested in the uncoated condition.
    -all tested parts are with silver plated.

    An explanation is required why the 12 cycle reuseability test samples appear to exhibit hardness exceeding the Prod S’d (e.g 58-60HRC).
    All the nuts are silver-coated during the tests in self-braking torque;
    the control nut (inspection tools), which is not coated and the resistance class , which is of a hardness between 58-60 HRC.

    Observations:
    The test data was confusing to extract & a presentation based on the proposed QTS would improve the approval processing time invested into these parts.

Leave a Reply

Your email address will not be published. Required fields are marked *

Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.