TCM 2 868-(MCR) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ249 Subcontract Surface treatment

QAR: Click Here
Conditions for approval required by:  Julien Gauther

4 Replies to “TCM 2 868-(MCR) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ249 Subcontract Surface treatment”

  1. In QTP, clause 1.1, why EN2786 (silver plating) is mentioned since this nut is only passivated?
    Same comment for clause 5.3.6.1.
    QTR and PFC deal with passivation as per EN2516, which is consistent with EN2906 nuts.

    In Process Flow Chart, for NDT, we have MPI (Magnetic Particle Inspection), which is inconsistent with material grade (austenitic stainless steel).
    Could you please provide detailed information about NDT carried out on this batch?

    Many thanks in advance,
    Regards.

    1. Hello Julien,
      The flow chart is modified
      I am missing the QTR without sylver plating it is a writing error