TCM 2 1546-(R) – Paolo Astori SPA – Gattico (IT) PQ395

QAR: Click Here
Conditions for approval required by:  Julien Gauther

5 Replies to “TCM 2 1546-(R) – Paolo Astori SPA – Gattico (IT) PQ395”

  1. Even though EN2906 does not require any passivation, these nuts were passivated, which is a really good practice. However, EN2907 were passivated as per EN2516 (see CoC) whereas EN2906 were passivated against AMS2700 (see Coc as well).
    Could you please clarify?
    EN2907-070: do we have a chance to get silver thicknesses values?
    Many thanks in advance,
    Best regards Julien

  2. Julien, below the reply to your comments managed with Stefano Giacometti (Paolo Astori)

    EN2906-070: have been passivated per EN2516 (meets AMS2700 requirements also). There was a typo on on FAI and TR shared. See the updated FAI and TR.

    EN2907-070: see updated FAI document with silver thickness values (FAI page 7).

    Best regards
    Piero

  3. Hello Piero,
    Many thanks to you and Stefano for your quick reply.
    All is fine for me now.
    Approved from my side.
    Have a nice day
    Regards Julien