TCM 2 1292-(R) – AHG Ateliers de la Haute-Garonne – Flourens (FR) PQ347

QAR: Click Here
Conditions for approval required by:  Julien Gauther

3 Replies to “TCM 2 1292-(R) – AHG Ateliers de la Haute-Garonne – Flourens (FR) PQ347”

  1. EN4072 screws have offset cruciform recesses. EN4072 specifies specific recess removal torque values. Thus, why, in both QTP and QTS, this test is “NA” for EN4072 screws?
    Hopefully, we have recess removal torque test results in relevant CoC/TR. This test is required only for Qualification as per ISO9152, not for Acceptance.
    Many thanks Daniel for complementary explanations about fatigue and coating tests.
    Best regards,
    Julien

  2. Due to the fact that AHG ( or other suppliers ) provides results for some tests which are not mandatory for acceptace as COC of material batch, TUS ( but which are from my point of view interesting for quality assurance of the product) my templates for QTP and QTS cover all tests .
    After, I customize it depending of the EN and if it is a new qualification or renewal dossier . It is why the recess test is “NA” for this reference following the acceptance test grid .

Leave a Reply to Julien Gauther Cancel reply

Your email address will not be published. Required fields are marked *