TCM 1 955-AHG Ateliers de la Haute-Garonne – Flourens (FR) EN2859 EN3035

QAR: Click Here
Conditions for approval required by:  Julien Gauther

3 Replies to “TCM 1 955-AHG Ateliers de la Haute-Garonne – Flourens (FR) EN2859 EN3035”

  1. EN2859-080:
    In QTR, page 10, stress relief after tempering: AIR2133 is written. Could you please replace AIR2133 by EN2133?
    Surface roughness on head bearing surface and shank: do you confirm that Ra max measured equals to 0,05 µm? (and not 0,5 µm?)

    EN2859-100:
    In QTR, page 10, stress relief after tempering: AIR2133 is written. Could you please replace AIR2133 by EN2133?

    EN3035-050:
    In QTR, page 11, stress relief after tempering: AIR2133 is written. Could you please replace AIR2133 by EN2133?
    In QTR, minimum tensile strength requirement written is 16,8 kN.
    This value is for MJ5 protruding head. EN3035 is a countersunk head screw with recess.
    Anyway, tensile test results are compliant. This is just a remark.

    Many thanks.
    Best regards.

    1. EN2859-080:
      In QTR, page 10, stress relief after tempering: AIR2133 is written. Could you please replace AIR2133 by EN2133?

      done : see new QTR ind E ( temp requirement have been updated. Nevertheless AHG was already in accordance with these values ( idem for de embrittlement )

      Surface roughness on head bearing surface and shank: do you confirm that Ra max measured equals to 0,05 µm? (and not 0,5 µm?)

      Done : see new QTR indE ( max is 0.4 µ)

      EN2859-100:
      In QTR, page 10, stress relief after tempering: AIR2133 is written. Could you please replace AIR2133 by EN2133?

      Done : see new QTR ind E

      EN3035-050:
      In QTR, page 11, stress relief after tempering: AIR2133 is written. Could you please replace AIR2133 by EN2133?

      Done see new QTR indE

      In QTR, minimum tensile strength requirement written is 16,8 kN.
      This value is for MJ5 protruding head. EN3035 is a countersunk head screw with recess.
      Anyway, tensile test results are compliant. This is just a remark.

      Test has been proceeded on bolt . there was a mistake in the QTR . New QTR ind has been modiified with the right requirement . in any case AHG was in accordance with the specification . as an evidence see the screen shot copy in supplementary document where you find the requirement of 1350 daN and the different tests values ( in blue)

Leave a Reply

Your email address will not be published. Required fields are marked *

Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.