TCM 1 841 – Howmet Fixations Simmonds – St Cosme en Vairais (FR) 6JSMR10209M

QAR: Click Here
Conditions for approval required by:  Julien Gauther

3 Replies to “TCM 1 841 – Howmet Fixations Simmonds – St Cosme en Vairais (FR) 6JSMR10209M”

  1. QTP: ISO8788:2020 is the latest edition. In QTP, ISO8788:2000 is listed. Could you please have a look at this? (Note: in QTR, ISO8788:2020 is mentioned)
    Incoming inspection after dry film lubrication: in test report RQ58947, go/no plug gauge (N°12276) is declared non-compliant. Could you please clarify?
    Hopefully, nut internal thread check with test bolts is compliant.
    Many thanks in advance,
    Best regards,
    Julien

  2. The year mentioned in the ISO8788 (QTP page 2 of 16) was a typo and the typo has been changed. See this in QTP rev A.
    The valid QTP in the report is now QTP rev A, EN2752-060.

    On the report RQ58947 the inspection was performed with 2 devices :
    – First with go gage and no go gage: result non conform
    – Second Inspection performed with test bolts reference GALAS 00165 , in this case the result is compliant .

    Kind Regards
    Kees

    In the QTR 9177 the inspection was performed only with test bolts GALAS00165 and the result is compliant.

    ISO 5858, clause 5.5.2. “Tread”, authorize to check the thread for nuts with MoS2 with a bolt.
    “A bolt with standard threads shall be capable of being freely screwed for at least one turn”.
    Also in accordance with ISO 5855-2 threads.

Leave a Reply

Your email address will not be published. Required fields are marked *

Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.