TCM 1 783-Paolo Astori SPA – Gattico (IT) product engineer

QAR: Click Here
Conditions for approval required by:  Julien Gauther

3 Replies to “TCM 1 783-Paolo Astori SPA – Gattico (IT) product engineer”

  1. Vibration test after 425°C baking: why tightening torque applied is 23 N.m?
    Metallurgical examinations: why EN3752 is called out?
    On ASD-CERT web site, in “manufacturing process” section, could you please remove the following sentence: “These values are in compliance with the requirements of the standard EN3720-050, EN3720-060, EN3720-100.”?
    Many thanks in advance,
    Best regards.

  2. Vibration test after 425°C baking: why tightening torque applied is 23 N.m?
    – -> Typo error. I can confirm that seating torque applied is 19 Nm as reported for vibration test at ambient temperature.

    Metallurgical examinations: why EN3752 is called out?
    –> Typo Error. Applicable tech spec is EN3152 (as reported on by metallurgical report of external laboratory) See Attached the QTR revised.

    On ASD-CERT web site, in “manufacturing process” section, could you please remove the following sentence: “These values are in compliance with the requirements of the standard EN3720-050, EN3720-060, EN3720-100.”?
    – -> Typo Error

Leave a Reply to Piero Visconti Cancel reply

Your email address will not be published. Required fields are marked *

Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.