Conditions for approval required by: Julien Gauther
_________________________
Certification of Aerospace Products to international quality Standards
Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.
Test Report :
Maybe add EN part reference in “customer part number”
Magnetic particle inspection:
279 parts is the batch size. As per ISO7689, tables 3 and 4, discontinuities are considered as major defect with AQL = 0,065%. So, sampling shall be 200 parts instead of 50. The down arrow in table 4 is applicable for Acceptance/Rejection criteria and related sampling as well.
AFS shall provide a declaration that they will now comply with this interpretation.
Many thanks in advance.