TCM 1 392-1-13 LISI Aerospace [Bestas] Gazemir (TR) EN4135-080, -100, -120

QAR: Click Here
Conditions for approval required by:  Heinrich Hackmann

2 Replies to “TCM 1 392-1-13 LISI Aerospace [Bestas] Gazemir (TR) EN4135-080, -100, -120”

  1. Comments to LISI
    EN4135 ; ASD-Cert 392-1-13
    QTR 008-18 ; issue September 2018

    1. Annex 1 Mechanical Test Results; Tensile Test EN 4135-080
    Please check if the “Minimum Tensile Requirement (KN) 35kN is correct. ISO 9152 require 46kN as a minimum.

    2. Annex 4 Statement of Inspection (general)
    For the Tensile Test on Finish Good the results are marked with
    e.g. NF means “No Failure”
    HR means “Head rupture”
    What the abbreviation for “TR” ?

    Heinrich Hackmann
    Airbus Defence and Space
    Rechliner Straße
    85077 Manching
    Date: 30.01.2020

    1. Hi Heinrich,

      1. Minimum tensile requirement for diameter 8 is 46kN. I have made a typo error on annex-1 requirement should be 46 instead of 35. You can see correct requirement (46kN mi.) on Annex-4
      2. TR means thread failure. Actually laboratory techician should indicate it as TF but as an old habit he have indicated it as TR.