TCM 1 1001-(MCR) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ542 Subcontract Surface treatment

QAR: Click Here
Conditions for approval required by:  Julien Gauther

3 Replies to “TCM 1 1001-(MCR) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ542 Subcontract Surface treatment”

  1. PFC, main titles: it would be preferable to distinguish nut internal process, cage internal process and nut + cage assembly process.
    CoC for passivation seems to be missing. Could you please add this document?
    Many thanks,
    Best regards.

    1. PFC, main titles: it would be preferable to distinguish nut internal process, cage internal process and nut + cage assembly process ==> Please find enclosed the QTR updated with cOC of passivation. Passivation on the washer was performed in ST Cosme Plant before fire.

      CoC for passivation seems to be missing. Please see enclosed the Flow chart with the title of the internal process updated.

      QTR & Flowchart have been enclosed in Additional Documents.
      Regards,
      Nadege Richard