TCM 1 1406-(R) – AHG Ateliers de la Haute-Garonne – Flourens (FR) PQ501

QAR: Click Here
Conditions for approval required by:  Piero Visconti

2 Replies to “TCM 1 1406-(R) – AHG Ateliers de la Haute-Garonne – Flourens (FR) PQ501”

  1. Dear Daniel,
    the ADHG letter indicating the number of parts produced in the last 3 years is missing and that there have been no complaints from users.

    Thank you.

    Piero

  2. dear piero
    Herewith the answer to your question

    indicating the number of parts produced in the last 3 years : see Appendix 8 ccp ( additional document)
    no complaints from users : see no complaint letter in additional document

    In addition, following remarks from julien GAUTHER on audit 1407 , I have added also a new IPFC including FPI inspection and H2 content test ( see red box “additional information” )