TCM 1 704-(R) – Arconic Fastening Systems & Rings – Portet sur Garonne (FR) PQ324

QAR: Click Here
Conditions for approval required by:  Julien Gauther

_________________________

One Reply to “TCM 1 704-(R) – Arconic Fastening Systems & Rings – Portet sur Garonne (FR) PQ324”

  1. Test Report :
    Maybe add EN part reference in “customer part number”

    Magnetic particle inspection:
    279 parts is the batch size. As per ISO7689, tables 3 and 4, discontinuities are considered as major defect with AQL = 0,065%. So, sampling shall be 200 parts instead of 50. The down arrow in table 4 is applicable for Acceptance/Rejection criteria and related sampling as well.
    AFS shall provide a declaration that they will now comply with this interpretation.
    Many thanks in advance.