  1. QTR EN4072-060
    Recess removal torque test: in QTR, torque applied is 14,1 N.m as stated in ISO9152, table 9 for recess code 6.
    However, EN4072 table 5 requires a “specific” recess removal torque equal to 16,4 N.m for recess code 6.
    Could you please clarify?

    “EN-4133-050-PFC-rev-01-signed-1” is incomplete (at the end of document). Could you please upload a full one? However, in Appendix E, we have a full PFC.

    Many thanks in advance and have a good day.
    Regards.
    Julien

    1. Wrong “Recess removal torque” on page 13 of 23 in the QTR has been corrected by the manufacturer and now displays the correct value > 16.4 Nm.

      Appendix G, form 2, in block 11 & 12, the “Recess removal torque” is also included.

      Appendix H, Test report, page 3 of 3 is the correct “Recess removal torque” value also included.