TCM 1 854 – Howmet Fixations Simmonds – St Cosme en Vairais (FR) 5JSF60045K

QAR: Click Here
Conditions for approval required by:  Julien Gauther

3 Replies to “TCM 1 854 – Howmet Fixations Simmonds – St Cosme en Vairais (FR) 5JSF60045K”

  1. In QTR, first page, could you please replace 1110 MPa by 1100 MPa? (just a typo)

    Surface roughness on bearing surface: could you please confirm value number 4? (0,062 µm)

    Torque-out test: applied torque is 7,2 N.m. This value is for anchor nuts made out of aluminum alloys baskets. However, this nut is made out of stainless steel (nut and basket). Thus, as per ISO5858, table 7, torque-out torque to be applied is 9 N.m.

    Many thanks in advance,
    Best regards.

    1. The typos as indicated in your comments above have been corrected.

      I replaced QTR No8155A with No8155B including the corrections

      1110 MPa replaced by 1100 MPa, see page 1 of 50.

      Surface roughness, value number 4? (0,062 µm) replaced by 0,620 µm, see page 22 of 50

      Torque-out test, torque 7,2 N.m. corrected and is now 9 N.m, see page 33 of 50.

      Regards
      Kees