QAR: Click Here
Conditions for approval required by: Julien Gauther
Certification of Aerospace Products to international quality Standards
Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.
In PFC, could you please replace “salt batch” by “salt bath”, “length” “by length”?
In FAI:
Thread major diameter “d max” shall be equal to D1 min – 0,025 as per EN4072, Table 1, note a.
D1min = 10 – 0,038 = 9,962 mm
d max = 9,962 – 0,025 = 9,937 mm instead of 10,000 mm written in FAI.
Actual values measured for major diameter are in line with d max = 9,937 mm, but the right d max shall be implemented for further production batches.
Many thanks in advance,
Regards.
EN4072-100-PFC-rev-02 and 38650EN4072-100017AE_F.A.I.2074086-rev-02 attached in “Additional documents” section answer the questions above.
Many thanks for replying.
Approved on my side.
Best regards.