Conditions for approval required by: Philip Edwards
Certification of Aerospace Products to international quality Standards
Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.
On ASD-CERT website, could you please, in section “Applicant’s internal company reference” replace EN3636 by EN3536?
Tensile test: in test report, EN3536-060 nuts have been tensile tested against 80% load (19100 N minimum). From my point of view, these nuts should have been tested under 100% load (23900 N minimum) as well. Could you please clarify?
In test report, “Dureté / hardness” section: HV5 9999 is written. This is just, to me, a typo and hopefully, hardness test results (HRC units) are listed in “Metallurgie” section. Actual sample size is in line with ISO5858, table 13, column B (destructive tests). Thus, this remark is not blocking, just something to point out.
Many thanks in advance
Best regards
Julien
Hello Mr Gauther,
with Mrs Lacombe find our reply :
On ASD-CERT website, could you please, in section “Applicant’s internal company reference” replace EN3636 by EN3536?
Updated by M. Diaz
Tensile test: in test report, EN3536-060 nuts have been tensile tested against 80% load (19100 N minimum). From my point of view, these nuts should have been tested under 100% load (23900 N minimum) as well. Could you please clarify?
3 parts were tested at 80 % ( value required 19100N , value tested 2055)
3 parts were tested at 100% ( value required 23900 , value tested 25095) see test report enclosed highlight in yellow
In test report, “Dureté / hardness” section: HV5 9999 is written. This is just, to me, a typo and hopefully, hardness test results (HRC units) are listed in “Metallurgie” section. Actual sample size is in line with ISO5858, table 13, column B (destructive tests). Thus, this remark is not blocking, just something to point out.
regards
Nadege/Geneviève