TCM 1 1416-(MCR) – Cherry Aerospace Div – Santa Ana (US) PQ687

QAR: Click Here
Conditions for approval required by:  Julien Gauther

3 Replies to “TCM 1 1416-(MCR) – Cherry Aerospace Div – Santa Ana (US) PQ687”

  1. FPI and dimensional checks for Acceptance: could you please give the sample sizes for these tests?
    Many thanks in advance
    Best regards
    Julien

  2. To validate this MCR, it has been carried out as an unwitnessed qualification. as this is the case the sample size for the dimensional is 46 pieces and the NDT should be 3 pieces, however SPS have check 10.

    as the total manufactured parts in this batch is 1500 pieces. When the batch is delivered the acceptance data provided will be based on 315 pieces as per table 3 and 4 of the technical specifiaction.

  3. Thanks Phil.
    All is fine for me now.
    Approved from my side.
    Have a nice day
    Best regards
    Julien

Leave a Reply

Your email address will not be published. Required fields are marked *

Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.