  1. EN4129-080013:
    Double shear test was not carried out on bolts due to length restriction. However, do we have double shear test results on specimens and/or another EN4129-080 bolt references available?
    Many thanks in advance
    Best regards
    Julien

    1. Double shear test was performed on EN4129-080032 part because it was required due to its length. You can find the CoC document attached.

      Thanks.
      Best Regards
      Sena.

  2. Many thanks for your speed!
    Sorry, could you please tell me where did you uploaded this additional CoC?
    Have a nice day
    Best regards
    Julien

    1. I uploaded it to select files. I also sent you the document by e-mail.

      Thanks.
      Best Regards.

      Sena.

  3. report update to say..

     The acceptance tests. (for Double shear tests please refer to the EN4129-080032 CoC)

    EN4129-080032 CoC is available in the QTR section of the report

  4. Many thanks to all of you.
    All is fine for me now, so, approved from my side.