TCM 1 1373-(R) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ249 EN2907-060

QAR: Click Here
Conditions for approval required by:  Julien Gauther

3 Replies to “TCM 1 1373-(R) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ249 EN2907-060”

  1. Test report (mfg batch #15152235): only pages 1 of 4 and 4 of 4 are available in QTR section.
    Could you please upload the full test report?

    Raw material: could you please give the relationship between EN raw material standards (EN2399/EN3639) called out by EN2907 and SAM0044 (material certificate)?

    Many thanks in advance
    Best regards
    Julien

    1. Test report (mfg batch #15152235): only pages 1 of 4 and 4 of 4 are available in QTR section.
      Could you please upload the full test report?

      ==> Please find enclosed the full test report . Sorry for the mistake.

      Raw material: could you please give the relationship between EN raw material standards (EN2399/EN3639) called out by EN2907 and SAM0044 (material certificate)?

      ==> See extract of SAM0044 with the EN Standards link.

      Nadège/Geneviève

  2. Many thanks for uploading new documents.
    In CoC, sample size for FPI is 125 parts.
    It should be 200 parts: EN3004, tables 3 and 4, discontinuities are ranked as major defect with AQL=0,065% and a down-arrow is marked against “1201-3200” mfg batch size range, indicating that sampling plan below shall be used.
    Many thanks in advance
    Best regards
    Julien