TCM 1 1612-(R) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ401

QAR: Click Here
Conditions for approval required by:  Julien Gauther

3 Replies to “TCM 1 1612-(R) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ401”

  1. In « Particular remarks » section, it is written :
    “Some brief comments regarding Test Rapport TR16310884, rev 1.
    The Sample size in this TR is complained with the ISO5858:1999 specification, Table 12 (Production Lot Quantity 2214, gives a sample size of 125 peaces). The ISO5858 doesn’t required NDT in acceptance test, it is only in qualification.”
    In Test Report TR16310884, rev 1, I cannot see any sample size for FP inspection.
    Even though ISO5858 does not require any NDT for Acceptance, could you please clarify? I assume that NDT data is available in nut test report (#15288840) and maybe in basket test report (#15288842).

    Many thanks in advance
    Best regards Julien

  2. Dear Mrs. Richard,
    Many thanks for these evidences.
    Approved from my side.
    Best regards
    Julien

Leave a Reply

Your email address will not be published. Required fields are marked *

Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.