TCM 1 1589-(R) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ519

QAR: Click Here
Conditions for approval required by:  Julien Gauther

One Reply to “TCM 1 1589-(R) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ519”

  1. Even though ISO5858 does not require any magnetoscopic or fluorescent penetrant inspection for Acceptance, HFS carried out this test on 200 parts, which is a really good practice (since a lot of technical specifications do require this kind of test for Acceptance).
    Hardness test results are available in “métallurgie” section, but “hardness/dureté” section has no results. As stated before, this is just a bug.
    Thus, approved from my side.
    Best regards
    Julien