TCM 2 1469-Howmet Fixations Simmonds – St Cosme en Vairais (FR) EN2680

QAR: Click Here
Conditions for approval required by:  Julien Gauther

3 Replies to “TCM 2 1469-Howmet Fixations Simmonds – St Cosme en Vairais (FR) EN2680”

  1. Tensile tests at 80% and 100% loads: in QTR, bolt reference mentioned is Inconel 718, passivated and with 1500 MPa UTS.
    However, on pictures after testing, bolts seem to be a bit yellowish (which would mean the use of cadmium plated steel test bolts). Therefore, could you please confirm test bolt references? Maybe this is just an optical effect.
    Test bolts at 80% and 100 loads may be different (higher UTS for 100% load test).
    Many thanks in advance
    Best regards
    Julien

Leave a Reply

Your email address will not be published. Required fields are marked *

Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.