QAR: Click Here
Conditions for approval required by: Julien Gauther

Certification of Aerospace Products to international quality Standards
Form restricted to registered, logged in users. Please return to the home page and use the Create Account option.
Tensile tests at 80% and 100% loads: in QTR, bolt reference mentioned is Inconel 718, passivated and with 1500 MPa UTS.
However, on pictures after testing, bolts seem to be “really” yellow (which would mean the use of cadmium plated steel test bolts). Therefore, could you please confirm test bolt references? Maybe this is just an optical effect.
Many thanks in advance
Best regards
Julien
I confirm that it was an optical effect . The test bolts used are Inconel 718 passivated
Many thanks Mrs. Richard.
All is fine for me now.
Approved from my side.
Best regards
Julien