TCM 1 1331-(R) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ205 EN3196-120

QAR: Click Here
Conditions for approval required by:  Julien Gauther

3 Replies to “TCM 1 1331-(R) – Howmet Fixations Simmonds – St Cosme en Vairais (FR) PQ205 EN3196-120”

  1. Tensile test: in TR, minimum tensile value requirement is 16,8 kN. I assume that this is a typo since, for tensile test, EN3196-120 nuts shall withstand 106,8 kN minimum. We have the same issue on actual results (17,64 kN).
    Could you please fix this?

    Self-locking torque test: what kind of test bolts have been used? Did we have some lubrication added for this test? (in TR, no information mentioned in related boxes)

    Many thanks in advance,
    Best regards,
    Julien

  2. TR14192742, rev 4 has been replaced by rev 5.
    In the TR 14192742, rev 5 the typos have been corrected and the correct data has also been”added in the relevant box of the TR “Self-locking test.