TCM 1 856 – Howmet Fixations Simmonds – St Cosme en Vairais (FR) 4070PH135M

QAR: Click Here
Conditions for approval required by:  Julien Gauther

4 Replies to “TCM 1 856 – Howmet Fixations Simmonds – St Cosme en Vairais (FR) 4070PH135M”

  1. In both QTP and QTR, ISO8788:2000 is mentioned. However, the latest edition of ISO8788 is: ISO8788:2020.
    Which one is applicable for this qualification?

    Salt spray test: in QTR, sample size is 8 whereas the picture shows 10 nuts. This is not blocking obviously, but shall we consider 8 or 10 tested nuts?

    Cadmium plating: is baking curve (after plating) available?

    Thank you in advance,
    Best regards.

    1. Dear Julien,
      Please you can find enclosed the deshydrogenation chart.
      I inform you as soon as I received additional information,
      S.Garcia

      1. Dear Julien,
        ISO8788 => The issue of ISO 8788 contains only editorial changes which have no impact on the part in question. What is more, the date of the standard has changed but not the issue.
        Salt Spray => the test was carried out on 10 samples by mistake instead of 8.

        Thank you in advance for your treatment,
        S.Garcia

  2. Dear Sébastien,

    All is clear for me now.
    The issue of ISO 8788 contains only editorial changes which have no impact on the parts.
    Salt spray test carried out on 10 nuts, so 2 extra tested parts, which is better.
    Approved on my side.
    Best regards.